Datasheet Reliability Report Package Information Order Sample  
Key Specifications
Part Number Description Status Supply Voltage(Nom)(V) No. of TX No. of RX Duplex Signaling Rate(Max)(Mbps) ESD Contact (kV) ESD Air (kV) Number of Nodes Common Mode Range(V) Fail Safe ICC(Max) (mA) Operating Temperature Range(℃) Pin/Package EV Kit Available?
UM3087EEPA Hot-Swappable Auto Polarity Reversal Half-duplex RS485 Transceiver Active 5 1 1 Half 2.5 ±8 ±15 256 -7 to 12 Idle, Open, Short 0.7 -40 to 85 8/DIP
View All>>
Product Description
 
The UM3087E series are +5.0V powered, ±15kV ESD protected, fail-safe, hot-swappable, auto polarity reversal RS-485 transceivers. The device includes fail-safe circuitry, which guarantees a logic-high receiver output when the receiver inputs are open, shorted or idle. This means that the receiver output will be logic high if all transmitters on a terminated bus are disabled (high impedance). The UM3087E features reduced slew-rate driver that minimizes EMI and reduces reflections caused by improperly terminated cables, allowing error-free data transmission up to 500kbps. All transmitter outputs and receiver inputs are protected to ±8kV using the Human Body Model and ±15kV using the IEC61000-4-2, Air-Gap Discharge.
The UM3087E includes cable auto-invert functions that reverse the polarity of the RS485 bus pins in case the cable is misconnected. Receiver’s full fail-safe features are maintained even when the receiver polarity has been reversed.
The transceivers typically draw 300μA of supply current when unloaded, or when fully loaded with the drivers disabled. The device has a 1/8-unit-load receiver input impedance that allows up to 256 transceivers on the bus and is intended for half-duplex communications.
 
Features
 
-Automatic Polarity Reversal RS-485 Transceivers
-I/O Logic Compatible with +3.3V & +2.5V Logic
-ESD Protection for RS-485 I/O Pins
 ±15kV—IEC61000-4-2, Air-Gap Discharge
 ±8kV—IEC61000-4-2, Contact Discharge
-True Fail-Safe Receiver
-Enhanced Slew-Rate Limiting
-Allows up to 256 Transceivers on the Bus
-Thermal Shutdown
-Current-Limiting for Driver Overload Protection
  
Typical Operating Circuits
 
 
 
Pin Configurations
 


Applications
 
-Smart Meters/Automated Meter Reading Systems
-Industrial-Control Local Area Networks
-PROFIBUS® and Other RS-485 Based Field Bus Networks
-Building Lighting and Environmental Control Systems
-Transceivers for EMI-Sensitive Applications
 
Communication Function Table
 
Table1. Transmitting                       
INPUTS
OUTPUTS
/RE
DE
DI
A
B
X
H
H/O
H
L
X
H
L
L
H
L
L/O
X
Z
Z
H
L/O
X
Shutdown
 
Table2. Receiving
INPUTS
OUTPUTS
/RE
DE
VID=VA-VB
RO
L
X
≥-50mV
H
L
X
≤-200mV
L
L
X
Open/Shorted
H
H
H
X
Z
H
L
X
Shutdown
 
 
 
 
 
 
 
 

H: High, L: Low, X: Do not care, Z: High impedance.
VA: Input Voltage of RS485 Non-Inverting Bus I/O terminal, VB: Input Voltage of RS485 Inverting Bus I/O terminal.
 
Ordering Information

Part Number
Mark Code
Operating Temperature
Package Type
Shipping Qty
UM3087EEPA
UM3087EEPA
-40°C to +85°C
DIP8
50pcs/Tube